½ÃÇè ¼Ò°³

¹æÆøÀÎÁõÀÇ Á¦Ç°Æò°¡´Â Å©°Ô ¹®¼­Æò°¡¿Í ½ÃÇèÆò°¡·Î ÀÌ·ç¾îÁö¸ç, ½ÃÇèÆò°¡´Â ÀÏ¹Ý ¿ä±¸»çÇ× ¹× °¢ ¹æÆø±¸Á¶ º° Çü½Ä½ÃÇèÀÌ ÁøÇàµÇ¾î¾ß ÇÕ´Ï´Ù.

Á¦°ø ºÐ¾ß

ÀÏ¹Ý ¿ä±¸»çÇ× Çü½Ä ½ÃÇè (IEC 60079-0 ¹× ISO 80079-36)
¿Âµµ½ÃÇè / Ãæ°Ý½ÃÇè / ³«ÇϽÃÇè / IP½ÃÇè / ³»¿­ ¹× ³»ÇÑ ½ÃÇè / ºñ±Ý¼ÓÀçÁúÀÇ Ç¥¸éÀúÇ×½ÃÇè / ¼ÒÇüºÎÇ° Á¡È­½ÃÇè / ºÎ½ÌÀÇ ÅäÅ©½ÃÇè / ³»±¤½ÃÇè µî
°¢ ¹æÆø±¸Á¶ º° Çü½Ä ½ÃÇè (IEC 60079 series ¹× ISO 80079-37)
ºÒ²ÉÁ¡È­½ÃÇè / ±âÁؾРÃøÁ¤ ½ÃÇè / ¼ö¾Ð½ÃÇè / Æø¹ß¾Ð·Â½ÃÇè / ÄÉÀ̺í ÀÎÀå½ÃÇè / ÆÛÁö½ÃÇè / Èñ¼®½ÃÇè / ±â´É½ÃÇè µî

ÇØ´ç Á¦Ç°

Æø¹ß¼º °¡½º ¹× ºÐÁøÀÇ ´ë±â°¡ Çü¼ºµÉ ¼ö ÀÖ´Â ±¤»ê, Ç÷£Æ®, ¼±¹Ú, Á¦Á¶°øÁ¤ µî°ú °°Àº ÇöÀå¿¡ »ç¿ëµÇ°Å³ª ¼³Ä¡µÇ´Â ±â±â.

»ê¾÷ ºÐ¾ß

½ÃÇè ±Ô°Ý

±¹³» : ¹æÈ£ÀåÄ¡ ¾ÈÀüÀÎÁõ°í½Ã
ÇØ¿Ü
IEC 60079-0 - Part 0: Equipment - General requirements - Àü±â±â±â ÀϹݿ䱸»çÇ×
IEC 60079-1 - Part 1: Equipment protection by flameproof enclosures "d" - ³»¾Ð¹æÆø±¸Á¶
IEC 60079-2 - Part 2: Equipment protection by pressurized enclosures "p" - ¾Ð·Â¹æÆø±¸Á¶
IEC 60079-5 - Part 5: Equipment protection by powder filling "q" - ÃæÀü¹æÆø±¸Á¶
IEC 60079-6 - Part 6: Equipment protection by oil immersion "o" - ¿ÀÀϹæÆø±¸Á¶
IEC 60079-7 - Part 7: Equipment protection by increased safety "e" - ¾ÈÀüÁõ¹æÆø±¸Á¶
IEC 60079-11 - Part 11: Equipment protection by intrinsic safety "i" - º»Áú¾ÈÀü¹æÆø±¸Á¶
IEC 60079-15 - Part 15: Equipment protection by type of protection "n" - ºñÁ¡È­¹æÆø±¸Á¶
IEC 60079-18 - Part 18: Equipment protection by encapsulation ¡°m¡± - ¸ôµå¹æÆø±¸Á¶
IEC 60079-28 - Part 28: Protection of equipment and transmission systems using optical radiation - ±¤Çйæ»ç¸¦ »ç¿ëÇÏ´Â Àü¼Û½Ã½ºÅÛ
IEC 60079-29-1 - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases - °¡¿¬¼º °¡½º¿ë °¡½º°ËÁö±â
IEC 60079-31 - Part 31: Equipment dust ignition protection by enclosure "t" - ºÐÁø¹æÆø¿ÜÇÔ
ISO/IEC 80079-34 - Part 34: Application of quality systems for equipment manufacture - ¹æÆøÁ¦Ç°»ý»êÇ°Áú ¿ä±¸»çÇ×
ISO 80079-36 - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements - ºñÀü±â±â±â ÀϹݿ䱸»çÇ×
ISO 80079-37 - Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" - ºñÀü±â±â±â º¸È£Çü½Ä

½ÃÇè Àåºñ

ÁÖ¿ä ½ÃÇèÀåºñ

  • Explosive test chamber (IEC 60079-1)

  • Spark ignition tester (IEC 60079-11)

  • Overpressure test facility (IEC 60079-1)

  • MESG tester (IEC 60079-20-1)

  • Thermal endurance test chamber (IEC 60079-0)

  • Small component ignition tester (IEC 60079-0)

´ã´çÀÚ

¿©¼®±¤ ¼¾ÅÍÀå

070-5083-2629

sky@icrqa.com

¼­È£¿µ ¼±ÀÓ

070-5083-2639

hys@icrqa.com

À±ÀçÀÍ ÀüÀÓ

070-5083-2654

yji@icrqa.com